VIPER SC+ Base™
Digital Infrastructure for Viper SC+ Series
The NextGen Viper SC+ Base Station™ eliminates the tradeoffs between speed, range and reliability. The Base Station is available in a standard or redundant configuration using a Software Defined Radio programmable for 100, 50, 25, 12.5 or 6.25 kHz channels. Redundant configuration features primary and backup radios with identical Ethernet MAC addresses. The VHF and UHF 12.5 kHz and 25 kHz Viper SC+ Base is also approved for ETSI and ACMA operation.
About Viper SC+ Base™
Versatile, Secure Communications with Multispeed Functionality
The NextGen Viper SC+ Base Station™ eliminates the tradeoffs between speed, range and reliability. The Base Station is available in a standard or redundant configuration using a Software Defined Radio programmable for 100, 50, 25, 12.5 or 6.25 kHz channels. Redundant configuration features primary and backup radios with identical Ethernet MAC addresses. The VHF and UHF 12.5 kHz and 25 kHz Viper SC+ Base is also approved for ETSI and ACMA operation.
Each Base Station offers rugged packaging, simple installation and flexible management for VHF, 200MHz, UHF and 900MHz licensed networks. Housed in a rugged, 19″ rack-mountable, aluminum case and built for industrial applications in a variety of environments, the Viper SC+ Base Station operates over an extended temperature range and provides worry-free operation in the roughest environments.
The Base Station operates the MultiSpeed Rate Controller supporting speeds up to 256 kbps at 100 kHz channel for FCC/IC and up to 48 kbps at 25 kHz channel for ETSI/ACMA operation. MultiSpeed operation allows each remote Viper SC+ to communicate to a Viper SC+ Base Station at the fastest channel speed supported by a given signal strength. MultiSpeed results in an adaptive network that is optimized for performance and reliability.
Centralized Management Platform
Viper SC+ Base Station can be remotely managed via an intuitive embedded webpage or SNMP. For medium to large deployments, Viper SC+ Base Station can be integrated with remote management systems.
- Standard and redundant
- Advanced security and encryption designed to meet FIPS 140-2
- VLAN support
- Warm and cold standby
- Fast failure detection through RF power sensor combined with RF traffic monitoring
- 8 pin I/O alarm port
- 2 relays – second relay configurable
as 2 digital inputs - Digital I/O can be configured to operate at 1.8V or 3.3V
- Store and forward repeater mode
Sales
Email: sales@nextgenrf.com
Phone: 507.514.6245
Support
Email: support@nextgenrf.com
Phone: 507.514.6246
Request A Quote
Viper SC+Base™ Technical Specifications
FCC/IC | |
Frequency Range | VHF: 136-174 MHz, 200: 215-240 MHz UHF: 406.1-470 MHz & 450-512 MHz 900: 880-902MHz & 928-960 MHz |
Channel Bandwidth | 6.25 kHz, 12.5 kHz, 25 kHz, 50 kHz and 100k Hz |
Output Impedance | 50 Ω |
Cold Start | 60 seconds |
ETSI/ACMA | |
Frequency Range | 142-174 MHz, 406.1-470 MHz, 450-512 MHz |
Channel Bandwidth | 12.5 kHz, 25 kHz (ETSI/ACMA) |
Output Impedance | 50 Ω |
Cold Start | 60 seconds |
Rx Current Drain (25° C, one unit powered) | |||
Power Out | DC Input 11V | DC Input 20V | DC Input 30V |
1.7 A (max) | 1.2 A (max) | 760 mA (max) | |
All Relays On | 1.5 A (typ) | 945 mA (typ) | 1.9A mA (typ) |
All Relays Off | 1.3 A (typ) | 1925mA (typ) | 622 mA (typ) |
Tx Current Drain, at Max (25° C, one unit powered) | |||
Power Out | DC Input 11V | DC Input 20V | DC Input 30V |
6.7 A (max) | 4.7 A (max) | 2.9 A (max) | |
All Relays On | 4.5 A (typ) | 3.1 A (typ) | 1.9 A (typ) |
All Relays Off | 4.3 A (typ) | 2.9 A (typ) | 1.7 A (typ) |
Tx Current Drain, at 1W (25° C, one unit powered) | |||
Power Out | DC Input 11V | DC Input 20V | DC Input 30V |
2.6 A (max) | 1.7 A (max) | 1.1 A (max) | |
All Relays On | 2.1 A (typ) | 1.4 A (typ) | 880 mA (typ) |
All Relays Off | 1.9 A (typ) | 1.2 A (typ) | 860 mA (typ) |
Primary Power 11-30 VDC, negative GND
Dimensions | |
Chassis | 16″ w x 4.75″ h x 11.375″ d in, (41 x 12 x 29 cm) |
Front Panel | 19″ w x 5.22″ h x 0.2 |
Weight | |
Standard | 11.5 lbs, (5.2 kg) |
Repeater/Redundant | 15 lbs, (6.8 kg) |
Mounting Options | 19″ rack mount |
Operating Temperature | -40° to +70° C, (-40° to +158° F) |
Specified Temperature | -30° to +60° C, (-22° to +140° F) |
Storage Temperature | –40° to +85° C, (-40° to +185° F) |
Operating Humidity | 5% to 95% Non-condensing RH |
Status Display | |
Controller LEDs | Power, Status, Fan Error |
Data LEDs | COM Data, Setup Data, Link/Act 1, Link/Act 2 |
Radio LEDs | Tx, Power, Error, Link/Act |
Other | Alarm Disabled, Manual Override (Redundant Models only) |
Antenna | N female (Tx/Rx) connector |
Serial SETUP | One RS-232, DE-9F port |
Serial COM | One RS-232, DE-9F port |
Ethernet | Two 10/100 Base-T/TX auto-MDIX, RJ-45 port |
I/O | 8 pin alarm |
Power | 4 pin main 4 pin internal auxiliary |